Pressure relief and pressure retention valve DAV for electrical control - open without current

1404 Pressure relief and pressure retention valve DAV for electrical control - open without current

Components

  • 1: Main valve
  • 2: Ball valve (A, B)
  • 3: Filter
  • 4: Orifice
  • 5: Throttle check valve
  • 6: Control valve
  • 7: Pressure gauge with ball valve
  • 8: Optical position indicator
  • 9: Electric solenoid valve
Article No. DN PN
(bar)
L
(mm)
weight
(kg)
Availability Watchlist
1404007000 1 1/2" 16 210 11.000 on demand
DAV for electrical control - open without current DN 1 1/2" PN 10/16
1404007000
Add to an existing list

1404008000 2" 16 210 11.000 on demand
DAV for electrical control - open without current DN 2" PN 10/16
1404008000
Add to an existing list

1404040000 40 16 200 15.750 on demand
DAV for electrical control - open without current DN 40 PN 10/16
1404040000
Add to an existing list

1404050000 50 16 230 16.250 on demand
DAV for electrical control - open without current DN 50 PN 10/16
1404050000
Add to an existing list

1404065000 65 16 290 21.300 on demand
DAV for electrical control - open without current DN 65 PN 10/16
1404065000
Add to an existing list

1404080000 80 16 310 27.400 on demand
DAV for electrical control - open without current DN 80 PN 10/16
1404080000
Add to an existing list

1404100000 100 16 350 35.400 on demand
DAV for electrical control - open without current DN 100 PN 10/16
1404100000
Add to an existing list

1404125000 125 16 400 51.500 on demand
DAV for electrical control - open without current DN 125 PN 10/16
1404125000
Add to an existing list

1404150000 150 16 480 76.000 on demand
DAV for electrical control - open without current DN 150 PN 10/16
1404150000
Add to an existing list

1404200000 200 10 600 114.600 on demand
DAV for electrical control - open without current DN 200 PN 10
1404200000
Add to an existing list

1404200016 200 16 600 114.600 on demand
DAV for electrical control - open without current DN 200 PN 16
1404200016
Add to an existing list

1404250000 250 10/16 730 247.000 on demand
DAV for electrical control - open without current DN 250 PN 10/16
1404250000
Add to an existing list

1404300000 300 10/16 850 359.000 on demand
DAV for electrical control - open without current DN 300 PN 10/16
1404300000
Add to an existing list

Physical characteristics

  • The main valve is a hydraulically operating diaphragm valve. The work energy is the inherent medium.
  • Most valve types operate purely hydraulically without any foreign energy.

Application

  • To use in drinking water systems (other media after consultation)
  • Sustaining the network pressure in a supply
  • Protecting the network by releasing excess pressure

Mode of operation

  • The pressure relief valve maintains constant the pre-set inlet pressure (p1). Any excess system pressure is relieved by fast opening of the valve. The closing procedure is slow in order to avoid shock pressure loads. Variable flow rates have no effect on the maintained pressure which is regulated by the control valve. The overpressure or maintained pressure can be set within the range of 2 bar to 16 bar (standard design). The valve is opened (started up) or closed via the electric solenoid valve.

Product information

  • To calculate the dimensions of the valve please refer to the following information:
  • Maximum and minimum inlet pressure (static and dynamic pressure ratios)
  • Required sustained pressure or dischargepressure
  • Voltage information for the solenoid valve
  • Maximum and minimum flow rates
  • Available line diameters and lengths
  • Construction of the valve (straight or angle design)
  • For the calculation basis, information on the loss of pressure and the characteristic values of the valve, please refer to the end of Chapter E.

Design

  • Design according to DIN EN 1074
  • Construction length acc. to DIN EN 558
  • Flange mass according to DIN 1092-2, to PN 25 DN 300
  • Pressure levels: PN 10 or PN 16 to DN 300, PN 25 to DN 200, higher pressures on request.
  • Nominal widths DN 50, DN 80, DN 100 and DN 150 available in angular design
  • Nominal widths 1 ½" and 2" with threaded connection (female thread)
  • Medium temperature up to 40°C

Installation and assembly

  • Shut–off valves should be fitted on both sides of the valve and a dirt trap should be installed on the inlet side of the valve. If the valve outlet flows to the outside or into a shaft, the outlet slider can be omitted. Depending on the installation situation, a mounting/dismounting adapter should be provided.

Vantages

  • Maintenance-free, non-rusting valve seat
  • Pressed-in seat
  • EWS-coating according to RAL GSK
mehr
  1. Watchlist
  2. Contact
    1. DE
    2. EN