Pressure reducing valve

1500 Pressure reducing valve

Components

  • 1: Main valve
  • 2: Ball valve (A, B, C)
  • 3: Filter
  • 4: Orifice
  • 5: Throttle check valve
  • 6: Control valve
  • 7: Manometer with ball valve (A, B)
  • 8: Optical position indicator (optional: Electrical position indicator, opening limiter)
Article No. DN PN
(bar)
L
(mm)
B1
(mm)
B2
(mm)
H1
(mm)
H2
(mm)
KVS
l/min.
weight
(kg)
NPK No.
411
Availability Watchlist
1500007000 1 1/2" 16 210 190 160 220 400 315 13.000 on demand
Pressure reducing valve DN 1 1/2" PN 10/16
1500007000
Add to an existing list

1500007025 1 1/2" 25 210 190 160 220 400 315 13.000 on demand
Pressure reducing valve DN 1 1/2" PN 25
1500007025
Add to an existing list

1500008000 2" 16 210 190 160 220 400 460 13.000 on demand
Pressure reducing valve DN 2" PN 10/16
1500008000
Add to an existing list

1500008025 2" 25 210 190 160 220 400 460 13.000 on demand
Pressure reducing valve DN 2" PN 25
1500008025
Add to an existing list

1500040000 40 16 200 190 160 220 400 315 15.000 833115 ex warehouse
Pressure reducing valve DN 40 PN 10/16
1500040000
Add to an existing list

1500040025 40 25 200 190 160 220 400 315 15.000 on demand
Pressure reducing valve DN 40 PN 25
1500040025
Add to an existing list

1500050000 50 16 230 190 160 220 400 506 16.200 833116 ex warehouse
Pressure reducing valve DN 50 PN 10/16
1500050000
Add to an existing list

1500050025 50 25 230 190 160 220 400 506 15.950 on demand
Pressure reducing valve DN 50 PN 25
1500050025
Add to an existing list

1500065000 65 16 290 190 160 240 400 725 21.200 833117 ex warehouse
Pressure reducing valve DN 65 PN 10/16
1500065000
Add to an existing list

1500065025 65 25 290 190 160 240 400 725 20.700 on demand
Pressure reducing valve DN 65 PN 25
1500065025
Add to an existing list

1500080000 80 16 310 190 180 250 400 1200 27.600 833118 ex warehouse
Pressure reducing valve DN 80 PN 10/16
1500080000
Add to an existing list

1500080025 80 25 310 190 180 250 400 1200 26.600 on demand
Pressure reducing valve DN 80 PN 25
1500080025
Add to an existing list

1500100000 100 16 350 220 200 280 400 2150 35.400 833119 ex warehouse
Pressure reducing valve DN 100 PN 10/16
1500100000
Add to an existing list

1500100025 100 25 350 220 200 280 400 1770 34.600 on demand
Pressure reducing valve DN 100 PN 25
1500100025
Add to an existing list

1500125000 125 16 400 230 210 360 500 2955 52.200 833141 ex warehouse
Pressure reducing valve DN 125 PN 10/16
1500125000
Add to an existing list

1500125025 125 25 400 230 210 360 500 2955 50.600 on demand
Pressure reducing valve DN 125 PN 25
1500125025
Add to an existing list

1500150000 150 16 480 250 220 400 500 4960 76.200 833142 ex warehouse
Pressure reducing valve DN 150 PN 10/16
1500150000
Add to an existing list

1500150025 150 25 480 250 220 400 500 4960 76.000 on demand
Pressure reducing valve DN 150 PN 25
1500150025
Add to an existing list

1500200000 200 10 600 260 250 450 500 7640 113.650 on demand
Pressure reducing valve DN 200 PN 10
1500200000
Add to an existing list

1500200016 200 16 600 260 250 450 500 7640 113.650 833143 on demand
Pressure reducing valve DN 200 PN 16
1500200016
Add to an existing list

1500200025 200 25 600 260 250 450 500 7640 113.650 833163 on demand
Pressure reducing valve DN 200 PN 25
1500200025
Add to an existing list

1500250000 250 10/16 730 320 270 520 600 11600 165.000 on demand
Pressure reducing valve DN 250 PN 10/16
1500250000
Add to an existing list

1500300000 300 10/16 850 420 280 510 600 24600 390.000 on demand
Pressure reducing valve DN 300 PN 10/16
1500300000
Add to an existing list

Physical characteristics

  • The main valve is a hydraulically operating diaphragm valve. The work energy is the inherent medium.
  • Most valve types operate purely hydraulically without any foreign energy.

Application

  • To use in drinking water systems (other media after consultation)
  • Reduction in pressure to supply the network
  • Emergency feed into a second network (network connections)

Mode of operation

  • The pressure reducing valve reduces a variable inlet pressure to a constant outlet pressure. Fluctuating inlet pressure and flow rate have no effect on the outlet pressure controlled by the control valve. The outlet pressure is adjustable in the range from 1.5 to 12 bar (standard design).

Product information

  • To calculate the dimensions of the valve please refer to the following information:
  • Maximum and minimum inlet pressure (static and dynamic pressure ratios)
  • Desired outlet pressure
  • Maximum and minimum flow rates
  • Possible requirement for extinguishing water
  • Available line diameters and lengths
  • Construction of the valve (straight or angle design)
  • For the calculation basis, information on the loss of pressure and the characteristic values of the valve, please refer to the end of Chapter E.

Design

  • Design according to DIN EN 1074
  • Construction length acc. to DIN EN 558
  • Flange mass according to DIN 1092-2, to PN 25 DN 300
  • Pressure levels: PN 10 or PN 16 to DN 300, PN 25 to DN 200, higher pressures on request.
  • Nominal widths DN 50, DN 80, DN 100 and DN 150 available in angular design
  • Nominal widths 1 ½" and 2" with threaded connection (female thread)
  • Medium temperature up to 40°C

Installation and assembly

  • Shut–off valves should be fitted on both sides of the valve and a dirt trap should be installed on the inlet side of the valve. Depending on the installation situation, a mounting/dismounting adapter and an aeration and ventilation system should be provided.

Vantages

  • Maintenance-free, non-rusting valve seat
  • Pressed-in seat
  • EWS-coating according to RAL GSK

Caution

  • Dimension H1 with electric position indicator and opening limiter is 110 mm higher up to DN 100 and 130 mm higher at DN 125 to DN 300.