Flow limitation valve MBV

1300 Flow limitation valve MBV

Components

  • 1: Main valve
  • 2: Ball valve (A, B, C)
  • 3: Filter
  • 4: Orifice
  • 5: Throttle check valve
  • 6: Control valve
  • 7: Differential pressure orifice plate
  • 8: Optical position indicator (optional: Electrical position indicator, opening limiter)
  • 9: Manometer with ball valve (A, B)
  • B: DN 40 to DN 150: 22 mmDN 200 to DN 250: 27 mmDN 300 to DN 400: 29 mm
  • X: 5 x DN line
  • Y: 3 x DN line
Article No. DN PN
(bar)
L
(mm)
weight
(kg)
Availability Watchlist
1300007000 1 1/2" 16 210 11.000 on demand
Flow limitation valve MBV DN 1 1/2" PN 10/16
1300007000
Add to an existing list

1300008000 2" 16 210 11.000 on demand
Flow limitation valve MBV DN 2" PN 10/16
1300008000
Add to an existing list

1300040000 40 16 200 15.750 on demand
Flow limitation valve MBV DN 40 PN 10/16
1300040000
Add to an existing list

1300050000 50 16 230 16.250 on demand
Flow limitation valve MBV DN 50 PN 10/16
1300050000
Add to an existing list

1300065000 65 16 290 21.300 on demand
Flow limitation valve MBV DN 65 PN 10/16
1300065000
Add to an existing list

1300080000 80 16 310 27.400 on demand
Flow limitation valve MBV DN 80 PN 10/16
1300080000
Add to an existing list

1300100000 100 16 350 35.400 on demand
Flow limitation valve MBV DN 100 PN 10/16
1300100000
Add to an existing list

1300125000 125 16 400 51.500 on demand
Flow limitation valve MBV DN 125 PN 10/16
1300125000
Add to an existing list

1300150000 150 16 480 76.000 on demand
Flow limitation valve MBV DN 150 PN 10/16
1300150000
Add to an existing list

1300200000 200 10 600 114.600 on demand
Flow limitation valve MBV DN 200 PN 10
1300200000
Add to an existing list

1300200016 200 16 600 114.600 on demand
Flow limitation valve MBV DN 200 PN 16
1300200016
Add to an existing list

1300250000 250 10/16 730 247.000 on demand
Flow limitation valve MBV DN 250 PN 10/16
1300250000
Add to an existing list

1300300000 300 10/16 850 358.000 on demand
Flow limitation valve MBV DN 300 PN 10/16
1300300000
Add to an existing list

Physical characteristics

  • The main valve is a hydraulically operating diaphragm valve. The work energy is the inherent medium.
  • Most valve types operate purely hydraulically without any foreign energy.

Application

  • To use in drinking water systems (other media after consultation)
  • Limitation of the inflow from a pressure zone into a lower pressure zone
  • Constantly maintaining a filter flow
  • The supply to a secondary network necessitates a limitation of the flow, so as to not endanger, for example, the extinguishing reservoir of the primary network (in combination with a reduction in pressure).

Mode of operation

  • The flow–control valve completely hydraulically ensures a pre–determined maximum flow, irrespective of any changes in the operating pressure. The nominal flow rate can be progressively varied up to ±15% via the control valve.

Product information

  • To calculate the dimensions of the valve please refer to the following information:
  • Maximum and minimum inlet pressure (static and dynamic pressure ratios)
  • Required flow rate
  • Permissible loss of pressure incl. measuring orifice (usually 0.5 bar over the valve and orifice plate)
  • Available line diameters and lengths
  • Construction of the valve (straight or angle design)
  • For the calculation basis, information on the loss of pressure and the characteristic values of the valve, please refer to the end of Chapter E.

Design

  • Design according to DIN EN 1074
  • Construction length acc. to DIN EN 558
  • Flange mass according to DIN 1092-2, to PN 25 DN 300
  • Pressure levels: PN 10 or PN 16 to DN 300, PN 25 to DN 200, higher pressures on request.
  • Nominal widths DN 50, DN 80, DN 100 and DN 150 available in angular design
  • Nominal widths 1 ½" and 2" with threaded connection (female thread)
  • Medium temperature up to 40°C

Installation and assembly

  • Shut–off valves should be fitted on both sides of the valve and a dirt trap should be installed on the inlet side of the valve. Depending on the installation situation, a mounting/dismounting adapter should be provided.
  • The orifice plate must be installed after the valve. It is recommended that the following measurements are taken into consideration:
  • X = 5 x DN, distance between the valve and the orifice plate in a straight line
  • Y = 3 x DN, distance after the orifice plate and the shut–off component, in a straight line

Vantages

  • Maintenance-free, non-rusting valve seat
  • Pressed-in seat
  • EWS-coating according to RAL GSK